We   have   obtained   spectra   of   IRAS04296  with  the  CCD
 (1140
1170  pixels)  equipped  echelle  spectrometer
 PFES  mounted at the prime focus of the 6m telescope of SAO RAS
 (Panchuk   et   al. 1998).   The   echelle-grating   with   
 and    with    a    blaze    angle    of    
 was  used.  A  diffracton  grating  with
 
 was  used as the cross-disperser. The camera
 has f=140mm. The size of input slit is 0.54arc sec.
We  observed  IRAS04296  on  October 07, 1996 (JD2450363.6) and
 February  26,  1997  (JD2450506.3).  The  echelle  frames with 25
 echelle-orders     cover     the     spectral     region    
4420-8300Å.     The     average    spectral
 resolution  was  0.4Å.  The  signal-to-noise ratio was in the
 range 50-110 for different spectral orders.
All usual procedures needed for echelle-images reduction (bias subtraction, cosmic ray removal, optimal order extraction, rebinning) were made using the ECHELLE context of the MIDAS system. A Gaussian function approximation was made for the measurement of equivalent widths. The comparison spectrum source was an argon-filled thorium hollow-cathode lamp.
The  distinctive  features  of the optical spectrum of the source
 IRAS04296  are  a  peculiar  profile  of the 
 line (see Fig.1), molecular emission bands and very strong
 absorption lines of ionized atoms of s-process elements
 (Y, Zr, Ba, La, Ce, Pr, Nd). For example, the equivalent widths
 of BaII lines (6141 and 6496Å) exceed 0.6Å.